NOTICE: Solid State Relays are Silent and
Offer Extremely Long Life, but May Not Function Properly when Subjected to
Radioactive Environments. Forced Air May be Required to Achieve Maximum Load
Rating. NCD does NOT Recommend Driving any Relay at Maximum Load. It is Not
Possible for NCD to verify Manufacturer Claims of Load Ratings. NCD Solid State
Relay Controllers have NOT been Tested at the Rated Loads. Solid State Relays
CANNOT be used for Switching DC loads. Solid State Relays May ONLY be used in
AC Switching Applications. Solid State Relays Require a Minimum Load, and will
NOT Function Correctly Unless Minimum Load Requirements are Met. External
Snubber Circuitry May be Required for Certain Applications. If a Device Turns
On, but Does Not Turn Off, this Usually Indicates a Need for a External Snubber
Circuit. This May Indicate Minimum Load Requirements Have Not Been Met. Please
Research Crydom Solid State Relays or be Familiar with this Technology Prior to
Purchase. Please Consult Crydom Engineers to Determine the Best Relay for Your
Application
www.crydom.com.