24-Channel ZB ZigBee Network Relay
ZB ZigBee Networking Relay
ZB ZigBee Wireless Networking is simply the hottest wireless technology of our time. Period. It's fast, it's very easy to use, highly reliable, and self healing. Three components are required for the ZB ZigBee Network, the Coordinator (C), the Router (R) and the Endpoint (E). Your computer can speak to a ZB ZigBee Network using a Coordinator. Think of the Coordinator as the interface to a ZB ZigBee Network. NCD Coordinators are equipped with a USB Interface. USB Coordinators mount as a Serial Port on your computer, and you will develop software that sends Serial commands at 115.2K Baud. The primary job of a router is to bridge the wireless gap between your computer (the Coordinator) and the device (Endpoint). If the Coordinator cannot speak to the Endpoint device because it is out of range, a Router can be used to bridge the two devices together. Endpoints are simply devices. With regard to NCD products, Endpoints can be relay controllers, data collection devices, PWM devices, and much more (and more coming).
Quick Summary of ZB ZigBee Wireless Networking
- A Coordinator Connects to your Computer

- A Coordinator is used to communicate with a ZB ZigBee Wireless Network
- A Coordinator can talk to up to 8 Endpoints or Routers in any combination
- A device is an Endpoint
- If a Coordinator cannot talk to an Endpoint because it is out of range, a Router can be used to bridge data between the Coordinator and the Endpoint
- A Router can also be an Endpoint device, but it's slower
24 Channel ZB ZigBee Relay
Our Twenty Four Channel ZB ZigBee Relays feature a wide range of controllers to fit just about any application!
DPDT and SPDT controllers are available with your choice of eight channel 8/10-Bit
Analog to Digital Conversionor
UXP Expansion Port. All Twenty Four Channel ZB ZigBee models feature the
ProXR Command Set and an
XR Expansion Portand all are of course
SignalSwitch compatible.
A/D Conversion
Analog to Digital Converter |
UXP Expansion
UXP Expansion Port
|
ProXR Command Set
XR Expansion Port |
 |
 |
 |
|
Onboard analog to digital conversion is available on selected models of these controllers! This will allow you to:
- Read light and temperature levels
- Easily activate relays when A/D limits are reached
- Detect audio levels in a room when connected to a microphone
- Read switches, potentiometers, and analog joysticks
- applications are limitless, and surprisingly easy to integrate
- Available on 2 - 32 channel ZB ZigBee boards
|
UXP is a new standardized data port, specifically for the purpose of speaking to various expansion modules. If the controller you are considering is equipped with a UXP port, you can take advantage of extended commands to speak to our growing line of I/O expansion modules. UXP in the part number allows you to:
- Add Contact Closure Inputs
- Add Analog to Digital Inputs
- Add Voltage Detectors
- Digital Potentiometer Outputs
- Available on 16, 24 & 32 channel ZB ZigBee Boards
|
Models with the ProXR suffix will feature the ProXR commend set. The ProXR series will allow you to:
- Send simple commands to activate relays
- Upgrade without having to re-write your software
- Activate up to 16 relay timers
- Control up to 256 total relays using the
XR expansion port
- Full backward/forward compatibility w/the
ProXR series command set
- Available on on all ZB ZigBee Networking Devices
|
24-Channel ZB ZigBee Relay Controller Boards
Displaying 1 - 12 of 12 Products in this Category.
- 24 Relays
- 10 Amp SPDT
- ZigBee Communication
- Range: 300 ft. to 1 mi.
- Ideal Use: Power Switching
- Taralist Series
- Learn More
- 24 Relays
- 5 Amp SPDT
- ZigBee Communication
- Range: 300 ft. to 1 mi.
- Ideal Use: Power Switching
- Taralist Series
- Learn More
- 24 Relays
- 10 Amp SPDT
- ZigBee Communication
- Range: 300 ft. to 1 mi.
- Ideal Use: Power Switching
- ProXR Series
- 8 A/D Inputs
- XR Expansion Port
- Learn More
- 24 Relays
- 1 Amp DPDT
- ZigBee Communication
- Range: 300 ft. to 1 mi.
- Ideal Use: Signal Switching
- ProXR Series
- 8 A/D Inputs
- XR Expansion Port
- Learn More
- 24 Relays
- 3 Amp DPDT
- ZigBee Communication
- Range: 300 ft. to 1 mi.
- Ideal Use: Signal Switching
- ProXR Series
- 8 A/D Inputs
- XR Expansion Port
- Learn More
- 24 Relays
- 5 Amp DPDT
- ZigBee Communication
- Range: 300 ft. to 1 mi.
- Ideal Use: Signal Switching
- ProXR Series
- 8 A/D Inputs
- XR Expansion Port
- Learn More
- 24 Relays
- 5 Amp SPDT
- ZigBee Communication
- Range: 300 ft. to 1 mi.
- Ideal Use: Power Switching
- ProXR Series
- 8 A/D Inputs
- XR Expansion Port
- Learn More
- 24 Relays
- 10 Amp SPDT
- ZigBee Communication
- Range: 300 ft. to 1 mi.
- Ideal Use: Power Switching
- ProXR Series
- XR and UXP Expansion Ports
- Learn More
- 24 Relays
- 1 Amp DPDT
- ZigBee Communication
- Range: 300 ft. to 1 mi.
- Ideal Use: Signal Switching
- ProXR Series
- XR and UXP Expansion Ports
- Learn More
- 24 Relays
- 3 Amp DPDT
- ZigBee Communication
- Range: 300 ft. to 1 mi.
- Ideal Use: Signal Switching
- ProXR Series
- XR and UXP Expansion Ports
- Learn More
- 24 Relays
- 5 Amp DPDT
- ZigBee Communication
- Range: 300 ft. to 1 mi.
- Ideal Use: Signal Switching
- ProXR Series
- XR and UXP Expansion Ports
- Learn More
- 24 Relays
- 5 Amp SPDT
- ZigBee Communication
- Range: 300 ft. to 1 mi.
- Ideal Use: Power Switching
- ProXR Series
- XR and UXP Expansion Ports
- Learn More