MirX .NET Ethernet Relay Controller Pair (MXNET)

2-Way LAN and Internet Communications Enabled Pair with Four 20-Amp Relay + 4 Contact Closure Inputs

Product Code: MirXR420_MXNET

MirXR420_MXNET MirX MXNET Controller
Control Relays in any two locations in the world with the MirXR420_MXNET. Need to control electronics from a remote location? A MXNET Series Pair is all you need.
Compliance to ROHS Standards



2-Way LAN and Internet Communications Enabled Pair with Four 20-Amp Relay + 4 Contact Closure Inputs

$580.00/ea
 

Setup for the MXNET versions is the same as the MIRXR430 shown above except the NXNET is connected to the internet through an Ethernet connection. The two MXNET boards can be located anywhere in the world and can find each other as long as each has a connection to the internet.

MXNET Series at a Glance

  • Internet or LAN Control with No Static IP Address Required
  • Sold in Pairs
  • Contact Closure Inputs and Outputs at Each Location
  • Each Device Controls the Other Device
  • Local Inputs Control Remote Relays and Remote Inputs Control Local Relays
  • 2-Way Communication with Verification
  • No Configuration, No Computers, and No Programming
  • Smart Mode provides Fast, Low Power Operation
 

This video is a basic introduction to the world of Computer Controlled Switching and Relays in general.
Also read our "Introduction to Computer Control" Article.

 

Learn the basics of the MirX controllers
Also read our Article on The MirX Controller.

 

Learn about the mechanics, applications, and tricks to Analog to Digital Conversion.
Also read our Article on Analog to Digital Conversion.

 

This movie will show you how to find the Com Port assigned to your Relay Controller.
The first half of the video will show you how to do so in Windows Vista and the second half is using Windows XP.

Resources:

This Product:

MirXR420_MXNET
Ratings AC DC
Voltage 240 24
Amperage 20 20
2-Way LAN and Internet Communications Enabled Pair with Four 20-Amp Relay + 4 Contact Closure Inputs
Stock#: MirXR420_MXNET $580.00
 

Development Kit:

MirXR420_MXNET-DK Development Kit
MirXR420_MXNET-DK

Including
2-MirXR420_MXNET
2-Power Supplies
Ethernet Cables
DVD & Manual
Stock#: MirXR420_MXNET-DK $673.00
 

Power Supply Available

PWR12 Power Supply
The PWR12 is regulated power supply providing clean power necessary for the performance of these boards
Stock#: PWR12 $48/pr
 

Questions?

AccessNCD

At AccessNCD we give you access to NCD technicians, developers and other customers! Our highly trained technicians and developers responding are the same ones designing and using these boards. If you are working on a sensitive project your questions can be posted privately without being posted to the public forum. Visit Today!

QUANTITY DISCOUNTS UP TO 100 PIECES ARE BUILT INTO OUR SHOPPING CART. CHANGE YOUR ORDER QUANTITY TO SEE QUANTITY PRICING.
Credit Cards Accepted
PayPal Accepted
Google Checkout Enabled
Shipping and Payment Information
Warranty Information
National Control Devices, LLC www.controlanything.com Since October, 1995 .

The Simplicity of MirX, The Power of .NET

Inputs on Each Controller Control the Relays at the Other Controller
Controllers  Communicate over a LAN or Internet via Ethernet Connection
Controllers Will Find Each Other No Matter Where They are in the Entire World

Control a Switch From a Distant Location

MirX-MXNET controllers provide you with an easy way to control a switch from a distant location using the Internet or LAN communications. MirX-MXNET controllers use a very sophisticated program to find each other no matter where they are in the entire world. They are permanently married together, and no matter how far apart they may be, they will always try to stay in communication with each other.

MirX-MXNET controllers are sold in pairs. Each MirX-MXNET controller has inputs and relays. One MirX-MXNET controller is installed locally while the other MirX-MXNET controller is installed remotely. The inputs on the local MirX-MXNET controller control the relays at the remote MirX-MXNET controller. The inputs on the remotely located MirX-MXNET controller control the relays on the local MirX-MXNET controller. MirX-MXNET controllers have one or more Contact Closure Inputs and one or more Contact Closure outputs.

Using this system, it is possible to install a light switch at your house that controls a light in China. Similarly, a light switch in China can control the lights at your house... and we have actually been testing this exact configuration for the past year as we have developed the firmware built into the MirX-MXNET controller.

Constant Communication

In order to use MirX-MXNET controllers over the internet, a 3rd party server is required. By default, we have configured every MirX-MXNET controller to use our two Lenux servers as a central hub and backup for MirX-MXNET communications. This server keeps each controller in communications with each other. However, you do not have to use our server; you can install our software on your own server and use it instead or in combination with our Lenux server. In fact, you can install our software on up to 4 servers. If one server is down, another server will be used as a backup path for communications. Your MirX-MXNET controller works right out of the box with our server, but you can add more servers if you want to increase the reliability.

If you prefer to use the MirX-MXNET controller over a local area network (LAN), no external server is required. LAN connected MirX-MXNET controllers will find each other directly (each location must be connected to an Ethernet router or switch).

Learn more about how MXNET works

Connection Through Mirror Server

When two mirror modules are located in different networks, they can talk to each other through the NCD Mirror Server. Mirror modules can connect to up to four servers at the same time. As long as one of the servers can be connected to, the mirror modules will work. You can use the preloaded servers or you can use the Configuration Utility to customize the board with your own server and three backup servers.
The server can be setup inside a local area network as long as both modules are able to access it.

The "ConfigureUtility" is used to configure the mirror modules. This program can list all available modules in the same local area network. There is a connection symbol for paired devices.


The Possibilities

The possibilities are endless with the MXNET series. They can be as simple or as complex as you want to make them. You can use a simple Push Button to activate the Relays or use a Current Sensor to constantly monitor the voltage running to a machine.

Remote Building Lights

You want to control the lights at a remote building from your house with a Push Button. Simply wire the lights to the board at the remote building and wire a Push Button to the necessary inputs on the board at your house and connect power and Internet to both. It's as simple as that.

Now replace the lights with any electronic device you need to control remotely and you have complete remote control from anywhere in the world.

Range:

MXNET pairs can communicate to each other from anywhere in the world using an internet connection. No Static IP Address is required. Simply plug the Ethernet and Power Cords in and give them a few minutes to find each other. After you wire the controlled devices in, you can control billboard lights in India, Runway Lights at an Airport, or simply lock your front door from the office.

Learn more about the Range of MXNET

Modes

MXNET Series Boards have two different modes that you can choose from, Smart Mode and Beacon Mode. Each has its own methods of how they send data and how they react to communication loss.

Smart Mode:

Smart Mode is the faster and lower energy option of the two. A board in Smart Mode only sends data to the paired device when a contact closure is detected. If communications are lost in Smart Mode all relays will turn off after a period of 30 seconds.

Beacon Mode:

A board in Beacon Mode constantly sends data to the paired device and waits for a change in the data being sent to it to change. If communications are lost the status of all relays will remain the same until communications are reestablished.

Learn more about the Modes of MXNET

Notes:

MXNET devices are only sold as a permanently married pair, pricing shown on our web site indicates pricing for the pair of controllers. Contact Closure Inputs may only be connected to switches, buttons, or sensors with Contact Closure capability. Not suitable for use in voltage detection applications. MXNET devices use Network Communications to ensure the remote device is properly functioning. The Busy LED is always used to indicate a properly functioning remote device. If you do not see the Busy LED flash, then the MirX controller is unable to communicate to the remote device. A flashing busy LED is your verification that all communications are functioning properly between MXNET controllers.

Inductive loads can lead to dropped communications between the two Devices. Customers who require inductive switching (such as motors, lights, pumps, solenoids, and Transformers) should visit the Induction Suppression portion of our web site.

Product Variations: MirC and MirX Series Controllers

NCD Currently offers two variations of this design: MirC and MirX.

MirX controllers have relays on both the remote and local device while MirC has relays on only one board which is controlled by a dedicated controller board.

Learn more about the difference between MirX and MirC


Attention: No Voltage Input

Please Note: Users must NEVER apply any voltage to an input on the Mir-X controller, these inputs are for Contact Closure connections only.


Resources

2-Way LAN and Internet Communications Enabled Pair with Four 20-Amp Relay + 4 Contact Closure Inputs

 
  Quantity in Basket: None
Code: MirXR420_MXNET
Price: $580.00
Shipping Weight: 4.00 pounds
 
Do you need two +12VDC Power Supplies?:
No Thanks, I already Have Two +12VDC Power Supplies
120VAC to 12VDC 1.25A 60Hz USA Computer Grade Regulated Power Supply (+$48)
100-240VAC to 12VDC 1.5A 50/60Hz International Computer Grade Regulated Power Supply with 4 Adapters (+$72)

Do you need two Ethernet Cables:
Yes! Add two 7' Ethernet Cables (+$20)
No Thonks, I don't need ethernet cables

Add Pluggable Connectors:
No Thanks
Add pluggable Connectors (+$12)

RoHS (Lead Free) Options:
Non-RoHS Compliant
RoHS Compliant (+$10)

 
Quantity:
 
2-Way LAN and Internet Communications Enabled Pair with Four 20-Amp Relay + 4 Contact Closure Inputs

Computer Control

Android Relays

iPhone Relays

Stand-Alone

Additional Products

Product Support

SECURE SERVER
Visit one of our other
great web sites:
www.SignalSwitch.com
www.relaycontrollers.com
English: 中文:

Attention

Please Note: Our office will be closed for Memorial Day on May 28th.